The new B Medical Systems Electronics offers a wide range of adjustment and diagnostic facilities as well as additional protection / warning operations (via external alarm operations, histories and individual display signals).
- Precision
- Premium
PRECISION LINE | Multifunctional electronics with digital display and easy access, in the door handle; compatible with °B Connected monitoring solution.
-
Key power switch O = OFF / I = ON
- To switch the unit on, turn the key switch to position „l“. The green power LED lights up
- After the self-check, the temperature inside the device is displayed
-
Digital display
During normal operation the display shows:
- Left-hand side: current time and internal temperature displayed in °C (Celsius) or °F (Fahrenheit) in increments of 0.1°
- Right-hand side: the maximum and minimum inside temperature
-
Acoustic and visual alarm signal
When an alarm occurs, the red alarm LED lights up and an acoustic signal sounds. The corresponding alarm message appears on the display alternately with the measured inside temperature. If several alarms occur simultaneously, the messages will be shown alternately.
-
Function buttons
- UP / DOWN buttons: navigation within the parameters and modification of their values
- ENTER button: use the ENTER-key to confirm the actual selection. This applies the parameter value. The change of a parameter only becomes effective when confirmed
- MUTE / BACK button: in case of an alarm, the acoustic alarm can be muted for a specified time. In Parameter-mode the same key acts a “BACK-button” to go one step back
- LIGHT button: allows to switch on or off the interior light of the device without opening the door (for B range)
-
USB-port
A USB port is available for data export only. Measured values of the display sensor are stored for at least 30 days (ring buffer) together with a time stamp.
PREMIUM LINE | All Premium models offer an optional 7” full touchscreen integrating all functionalities.
-
Power switch OFF / ON
- To switch on press the ON/OFF button for 1 second. The green LED will light up
- Switch off protected by a password. The door will automatically unlock before powering down
-
Digital color 4,3″ display
During normal operation the display shows:
- At the top: current voltage, current time, defrosting (for F range) and gasket heater (for F and U ranges)
- Left-hand side: internal temperature displayed in °C (Celsius) or °F (Fahrenheit) in increments of 0.1°
- Right-hand side: temperature of the regulation sensor. Displaying this temperature can be disabled through the settings
-
Acoustic and visual alarm signal
When an alarm occurs, the red alarm LED lights up and an acoustic signal sounds. The corresponding alarm message appears on the display together with the measured inside temperature. If several alarms occur simultaneously, the messages will be shown alternately.
-
Capacitive buttons
- ARROW buttons: select screen items with the arrow buttons. In the parameter editing mode, the arrow buttons are used to change values
- ENTER button: activates the currently selected item
- BACK button: goes one level upwards in the menu tree structure. It also serves as “escape” button
- DOOR UNLOCK button: unlocks the door of the device
- MENU button: opens the menu screen
- ALARM MUTE button: deactivates the acoustic alarm for a predefined period of time
- LIGHT button: allows to switch on or off the interior light of the device without opening the door (for B range)
-
USB-port & SD-card-slot
-
New 7” full touchscreen.
- Discover the ultimate control experience with the new B Medical Systems 7’’ full touchscreen display.
- More confortable, more functionalities, no compromise!